Static Relay
Description
Static relay are present on OI-RelayLP module. You can use them to commute alternative voltage.
Characteristics
Requirements |
Value |
Remark |
---|---|---|
Maximum voltage (AC) |
400V (RMS) |
|
Maximum current |
1A |
|
Internal fuse protection |
1A |
|
Isolation |
5000VDC |
Code examples
The example code above demonstrates how to set the relay on an OI-RelayLP module.
#include "OpenIndus.h"
#include "Arduino.h"
OIRelay relay;
void setup(void)
{
/* Nothing to do in setup */
}
void loop(void)
{
/* Activate all */
relay.digitalWrite(RELAY_1, HIGH);
relay.digitalWrite(RELAY_2, HIGH);
relay.digitalWrite(RELAY_3, HIGH);
relay.digitalWrite(RELAY_4, HIGH);
relay.digitalWrite(RELAY_5, HIGH);
relay.digitalWrite(RELAY_6, HIGH);
delay(1000);
/* Deactivate all */
relay.digitalWrite(RELAY_1, LOW);
relay.digitalWrite(RELAY_2, LOW);
relay.digitalWrite(RELAY_3, LOW);
relay.digitalWrite(RELAY_4, LOW);
relay.digitalWrite(RELAY_5, LOW);
relay.digitalWrite(RELAY_6, LOW);
delay(1000);
}